Site-directed spin labeling
|
Site-directed spin labeling is a technique for investigating protein local dynamics using electron spin resonance. The theory of SDSL is based on the specific reaction of spin labels with amino acids. A spin label's built-in protein structure can be detected by EPR spectrometry.
SDSL is also a useful tool in examinations of protein folding process.
Spin labeling
Site-directed spin labeling (SDSL) was pioneered in the laboratory of Dr. W.L. Hubbell. In SDSL, sites for attachment of spin labels are introduced into recombinantly expressed proteins by site-directed mutagenesis. Functional groups contained within the spin label determine their specificity. At neutral pH, protein thiol groups specifically react with the functional groups methanethiosulfonate, maleimide, and iodoacetamide, creating a covalent bond with the amino acid Cys. Spin labels are a unique molecular reporter, in that they are paramagnetic (contain an unpaired electron). Spin labels were first synthesized in the laboratory of H. M. McConnell in 1965. Since then, a variety of nitroxide spin labels have enjoyed widespread use for the study of macromolecular structure and dynamics because of their stability and simple EPR signal. The nitroxyl radical (N-O) is usually incorporated into a heterocyclic ring (eg pyrrolidine), and the unpaired electron is predominantly localized to the N-O bond. Once incorporated into the protein, a spin label's motions are dictated by its local environment. Because spin labels are exquisitely sensitive to motion, this has profound effects on its EPR spectrum.
SDSL Research Groups
David S. Cafiso
Adrian Gross
Wayne L. Hubbell
Peter Qin
John Voss
Spin labeling procedure
An example of spin labeling procedure:
Materials:
Procedure:
- Mix 0.33 mg of SL with 0.025 ml acetone.
- Mix 6 mg of cytochrome c with 0.5 ml of buffer.
- Add SL solution into the protein mixture.
- Incubate for 1 hour in a dark place.
- Execute dialysis in the same buffer overnight at 4oC.
- Check concentration using spectrophotometric method.
- Store at -70oC.
|